Clearances to NFPA 211 Protected Surfaces
You can reduce the clearances to combustible surfaces by
using any National Fire Protection Agency (NFPA)
approved wall protection system. Please refer to NFPA
211 for specifications and complete details. You can
obtain this information directly from NFPA.
Clearances to combustible surfaces can be reduced by
using any NFPA approved wall protection system.
REFER TO NFPA 211 FOR SPECIFIC AND
COMPLETE DETAILS:
National Fire Protection Agency
Battery March Park
Quincy, MA 02269
1-800-344-3555
1-617-770-3000
CLEARANCE TO COMBUSTIBLES
COMBUSTIBLE MANTLE
SIDE WALL
SIDE
TRIM
Figure 5 Clearance to Combustibles
A. side wall = 13”
B. mantle and top trim = 34”
B. mantle/ with mantle shield kit = 22”
C. trim = 3”
REMOVING THE BAFFLE
In order to connect the flue to the Morgan, you will need
to remove and install the baffle. Use Figure 6 to refer to
while removing and replacing the baffle.
BE CAREFUL WHEN HANDLING THE BAFFLE,
NOT TO PUNCTURE THE CERAMIC BOARD
To remove the baffle:
1. Lift the front of the baffle. This relieves the
weight from, and unlocks the shelf tabs.
2. Pull forward to free the baffle.
3. The baffle should now be free to drop down and
pull out of the front door, or rest on the floor of
the insert
Once the baffle is removed from the unit, you will have
direct access to the flue collar, and all venting connections
To install the baffle, reverse the order of removing the
baffle.
Shelf tabs
Baffle
sleeves
Figure 6 Baffle Placement
V
ENTING COMPONENTS AND CONFIGURATION
It is very important to follow minimum clearances for
chimney connectors to combustibles such as walls and
ceilings when installing the stove near non-
combustible surfaces
Single wall connector is 24 MSG or 25 MSG blued
steel stovepipe.
Double wall connector (close clearance pipe) which
must be used with a listed factory-built “Type HT"
chimney also may be used with a masonry chimney to
reduce clearances, is available from several
manufacturers, your dealer can help you choose.
Some air insulated connector pipe models available
are Simpson Dura Vent DVL and Metalbestos DS.
Security, GSW and Ameritec also have acceptable
close clearance connector pipe.
Chimney connector shall not pass through floor or
ceiling, nor any attic or roof space, closet or similar
concealed space. Where passage through a wall or
partition of combustible construction is desired, the
installation shall conform to NFPA 211 or CAN/CSA
- B365.